Pressure Sensor
E8CB/E8CC
Flat-pack, Slim, DIN-rail Mount Pressure Sensor H Withstands a pressure of 490 kPa
(71 psi) H Easy pressure setting with a two-turn pressure adjuster H Linear analog output H E8CC has digital display
Ordering Information
J SENSOR
Digital display Pressure range No Positive pressure Negative pressure Yes Positive pressure Negative pressure Positive pressure 0 to 98 kPa (0 to 14.2 psi) 0 to - 101 kPa (0 to - 14.6 psi) 0 to 98 kPa (0 to 14.2 psi) 0 to - 101 kPa (0 to - 14.6 psi) 0 to 980 kPa (0 to 142.1 psi) ON/OFF output NPN open collector Linear output 1 to 5 V Part number E8CB-01C E8CB-CN0C2B E8CC-A01C E8CC-AN0C E8CC-B10C
www..com
2
E8CB/E8CC
E8CB/E8CC
Specifications
J RATINGS/CHARACTERISTICS
Item/Model E8CB-01C E8CBCN0C2B (See Note 2.) E8CC-A01C E8CC-AN0C (See Note 2.) E8CC-B10C
Supply voltage Current consumption Pressure type Permissible pressure range (See Note 2.) Pressure setting range ( ) (See Note 2.) Display value Reference value Display value Reference value Pressure indication unit Withstand pressure Applicable material Repeat accuracy (ON/OFF output) Accuracy (linear output) Differential travel (ON/OFF output) Linearity (linear output) Response time Linear output ON/OFF output Load current Output applied voltage Residual voltage Circuit protection Display (See Note 1.) Display accuracy
12 to 24 VDC 10% with a ripple (p-p) of 5% max. 20 mA max. Gauge pressure 0 to 1 kgf/cm2 0 to 98 kPa (0 to 14.2 psi) 0 to 1 kgf/cm2 0 to 98 kPa (0 to 14.2 psi) --490 kPa (71 psi) 0 to - 76 cmHg 0 to - 101 kPa (0 to - 14.6 psi) 0 to - 76 cmHg 0 to - 101 kPa (0 to - 14.6 psi) 0 to 98 kPa --(0 to 14.2 psi) 0 to 98 kPa --kPa 490 kPa (71 psi) 1.5 MPa (217.5 psi) 0 to - 101 kPa --(0 to - 14.6 psi) 0 to - 101 kPa --0 to 980 kPa --(0 to 142.1 psi) 0 to 980 kPa --30 mA max.
Noncorrosive and nonflammable gases 1% FS max. 3% FS max. 2% FS max. 1% FS max. 5 ms max. 1 to 5 V with an output impedance of 20 and a permissible resistive load of 10 k min. NPN open collector 80 mA max. 30 VDC max. 1 V max. (with a load current of 80 mA) and 0.4 V max. (with a load current of 20 mA) Reversed power supply connection and load short-circuiting Red LED ON with output transistor turned ON --21/2-digit display Red LED ON with output transistor turned ON 3% FS 1 digit max. within a temperature range from 0C to 50C (32F to 122F) 4% FS 1 digit max. within a temperature range from 50C to 55C (122F to 131F) 5% FS 1 digit max. within a temperature range from 0C to - 10C (32F to 14F)
www..com
3
E8CB/E8CC
E8CB/E8CC
Item/Model
E8CB-01C
E8CBCN0C2B (See Note 2.)
E8CC-A01C
E8CC-AN0C (See Note 2.)
E8CC-B10C
Ambient temperature Ambient humidity Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection (See Note 3.) Pressure port Connection method Weight Pressure port
Operating: - 10C to 55C (14F to 131F) with no icing Storage: - 25C to 70C (- 13F to 158F) with no icing Operating/Storage: 35% to 95% (with no icing) 0.12% FS/C between 0C and 50C (32F to 122F) and 0.2% FS/C max. between - 10C and 0C or 50C and 55C (122F to 131F) 1.5% FS max. 50 M min. (at 500 VDC) between current carrying parts and case 1,000 VAC for 1 min 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s2 (328 ft/s2) for 2 hours each in X, Y, and Z directions 1,000 m/s2 (3280 ft/s2) 3 times each in X, Y, and Z directions IEC60529 IP50 Aluminum Prewired (standard cable length: 2 m) Approx. 70 g (2.47 oz) NPT 1/8 and M5 female screws Approx. 80 g (2.82 oz)
Note: 1. The 21/2-digit display refers to a display in which the third digit displays only 0 or 1. 3rd digit 2nd digit 1st digit
0 or 1
0 to 9
0 to 9
2. These models are negative-pressure models. 3. E8CB and E8CC are not oil resistant or water resistant.
Engineering Data
J TEMPERATURE VS LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CB-01C
Linear output fluctuation (% FS)
J PRESSURE VS LINEAR OUTPUT VOLTAGE (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS) Pressure (kgf/cm2)
www..com
Temperature (C)
4
Linear output voltage (V)
E8CB/E8CC
J TEMPERATURE VS OPERATING PRESSURE (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS)
E8CB/E8CC
J LINEARITY (TYPICAL)
E8CB-01C
Linearity deviation (%FS)
Temperature (C)
Pressure (kgf/cm2)
J VOLTAGE VS. OPERATING PRESSURE FLUCTUATION (TYPICAL)
E8CB-01C
Operating pressure fluctuation (% FS)
J VOLTAGE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CB-01C
Linear output fluctuation (% FS)
Voltage (V)
Voltage (V)
J TEMPERATURE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CC-A01C
Linear output fluctuation (% FS)
J PRESSURE VS. LINEAR OUTPUT VOLTAGE (TYPICAL)
E8CC-A01C
www..com
Linear output voltage (V)
Temperature (C)
Pressure (kgf/cm2 ) Pressure (cmHg) Pressure (kPa)
5
E8CB/E8CC
J TEMPERATURE VS. OPERATING PRESSURE (TYPICAL)
E8CC-A01C
Operating pressure fluctuation (% FS)
E8CB/E8CC
J LINEARITY (TYPICAL)
E8CC-A01C
Linearity deviation (%FS)
Temperature (C)
Pressure (kgf/cm2 ) Pressure (kPa)
J VOLTAGE VS. OPERATING PRESSURE FLUCTUATION (TYPICAL)
E8CC-AN0C
Operating pressure fluctuation (% FS)
J VOLTAGE VS. LINEAR OUTPUT FLUCTUATION (TYPICAL)
E8CC-AN0C
Linear output fluctuation (% FS)
Voltage (V)
Voltage (V)
www..com
6
E8CB/E8CC
E8CB/E8CC
Operation
J E8CB/E8CC PRESSURE SENSOR
Output configuration NPN output Model Timing Charts Output Circuits
E8CB-01C, E8CC-A01C, E8CC-B10C
Pressure (kgf/cm2 )
1
Setting
0 ON OFF Indicator ON OFF Main Mi circuit 0 Pressure (cmHg) Operation indicator Brown Load White (ON/OFF) Black (linear output) Load Blue 0V - 76 Output ON OFF Indicator ON OFF
Output
E8CB-CN0C2B, E8CC-AN0C
Setting
www..com
7
E8CB/E8CC
J CORRECT USE
Adjustment (E8CC)
1. Set the mode selector to SET. 3. Set the mode selector to RUN.
E8CB/E8CC
2. Turn the pressure adjuster to the desired pressure.
The E8CC has normal output in the SET mode. Changing the pressure setting is possible in RUN mode by turning the pressure adjuster. Do not turn the pressure adjuster after it has been set to the desired pressure.
Screwdriver
0
- 76 -
Indication
Display Mode Operating status Normal Normal Abnormal pressure imposition Description Permissible range Positive pressure E8CC-A01C E8CC-B10C 0 to 980 kPa (0 to 142.1 psi) Displays pressure within the permissible range. Displays the ON-point pressure within the permissible range Positive Pressure: Indicates that the imposed pressure is lower than the permissible range. Negative Pressure: Indicates that the imposed pressure is higher than the permissible range. The E8CC is in normal output operation in both cases. SET Abnormal pressure setting Positive Pressure: Indicates that ON-point pressure value is lower than the permissible range. Negative Pressure: Indicates that ON-point pressure is higher than the permissible range. The E8CC is in normal output operation in both cases. 0 to 98 kPa (0 to 14.2 psi) Negative pressure E8CC-AN0C 0 to - 101 kPa (0 to - 14.6 psi) -
30
(for 30 kPa)
RUN SET RUN
--
ff
RUN
Abnormal pressure imposition Abnormal pressure setting
Indicates that the imposed pressure is higher than the permissible range. Positive Pressure: Indicates that ON-point pressure value is higher than the permissible range. Negative Pressure: Indicates that ON-point pressure is lower than the permissible range. The E8CC is in normal output operation in both cases.
---
SET
0 to - 101 kPa (0 to - 14.6 psi) -
RUN www..com Load
le 5h
SET RUN SET
overcurrent Element destruction
Indicates that the output transistor has excessive load current. The result is that the output of the E8CC is turned OFF. This display flashes until the condition returns to normal. Check the output OFF normal wiring if this display flashes. Indicates that the Pressure Sensor element is damaged due to the imposition of excessive pressure or for other reasons, in which case the output of the E8CC turns OFF. If this display appears, the reasons OFF appears E8CC can no longer be used.
8
E8CB/E8CC
E8CB/E8CC
Dimensions
Unit: mm (inch)
J E8CB
Operation indicator 36.6 (1.44) 27.4 (1.08)
Pressure adjuster 52.5 (2.07) 40.5 (1.59) 3.75 (0.15) 26.8 (1.06) 25 (0.98) 8.5 (0.34) Two, M4 mounting holes 19 (0.75) 12.5 (0.49) 15 (0.59) NPT 1/8
M5 depth: 7.5 (0.30)
4 (0.16)
4-dia. vinyl-insulated round cable with 4 cores; standard length: 2 m
3 (0.12)
J E8CC
51.2 (2.01) 36.1 (1.42) 13.9 (0.55)
Operation indicator 2.6 (0.10) Display 17 (0.67)
20.6 (0.81)
2 (0.08) Pressure adjuster Display mode selector 8.5 (0.34) Two, M4 mounting holes 19 (0.75) NPT 1/8
67 (2.64) 55 (2.17) 3.75 (0.15) 29.5 (1.16) 28 (1.10)
11.3 (0.44) 56.2 (2.21) 4-dia. vinyl-insulated round cable with 4 cores; standard length: 2 m
12.5 (0.49) 15 (0.59)
M5 depth: 7.5 (0.30)
3 (0.12)
www..com
9
E8CB/E8CC
J MOUNTED TO A DIN-RAIL MOUNTING BRACKET
67 (2.64) 55 (2.17) 3.75 (0.15) 29.5 (1.16) 28 (1.10) 5.5 (0.22) 8.5 (0.34) Two, M4 mounting holes 19 (0.75) 18 (0.71)
E8CB/E8CC
NPT 1/8
11.3 (0.44)
M5 depth: 7.5 (0.30) 1.5 (0.06) 15 (0.59)
2
3 56.3 6 (0.12) (2.22) (0.24) DIN-rail mounting 4-dia. vinyl-insulated round cable with 4 cores; standard length: 2 m
2.6 (0.10)
Precautions
J MOUNTING
Diaphragm
If the diaphragm is damaged, the Pressure Sensor will not operate correctly. Do not insert a screwdriver or steel wire into the pressure port. The pressure port has an NPT 1/8 taper screw and M5 female screw. Apply sealing tape around the female taper screw so that no pressure leakage will occur. Make sure that the tightening torque of the M5 female screw is 3.9 N S m (2.87 ft * lbs) or less. If the Pressure Sensor is directly connected to a conduit, be sure to apply a wrench to the pressure port, not to the plastic case.
J DIN-RAIL MOUNTING BRACKET (E8CC)
Mounting
* * * Fit the front part onto the bracket. Press the rear part onto the bracket. Apply a flat-blade screwdriver to the rear hook. Then the Pressure Sensor can be removed easily.
Removing
DIN-rail mounting bracket (provided with each model)
J WIRING
Pressure port
If no linear output is used, cut off the black lead wire and apply insulation tape to the lead wire so that it will not come in contact with any other terminal.
www..com
10
E8CB/E8CC
E8CB/E8CC
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
www..com
R
OMRON ELECTRONICS LLC
1-800-55-OMRON
Cat. No. CEDSAX4 11/01
One East Commerce Drive Schaumburg, IL 60173
OMRON ON- LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci -
OMRON CANADA, INC.
416-286-6465
885 Milner Avenue Scarborough, Ontario M1B 5V8
Specifications subject to change without notice.
Printed in U.S.A.


▲Up To Search▲   

 
Price & Availability of E8CB-01C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X